Mubychem Group, is a mature manufacturing company since generations. Engaged in manufacture and supply of Pharmaceutical Intermediates and Excipients, Oil field & fracturing chemicals, Specialty tailor made grades of chemicals in India. With several manufacturing facilities in India and world wide contacts and toll manufacturers we are exporting to all the countries in the world..
The company and associated units have certificates & accreditations like FDA - GMP approval; ISO-9001 Certified; "REACH" Registered; ISO-22000; Kosher Certified; Halal Certified; HACCP. We offer Commercial Pure & Pharmacopoeia IP BP USP FCC Food Grade ACS AR Analytical Reagent Grades of Chemicals
Potassium Iodide Manufacturers, SDS MSDS Sheet
Potassium Iodide ACS AR Analytical Reagent FCC Food grade Manufacturers
Potassium Iodide SDS MSDS Sheet, Material Safety Data Sheet
1. Product Identification
Synonyms: Knollide; Potide; Iodic Acid Potassium Salt, Hydroiodic Acid Potassium Salt
CAS No.: 7681-11-0
EINECS EC Number: 231-659-4
Molecular Weight: 166
Chemical Formula: KI
R22 Harmful if swallowed.
R36/38 Irritating to eyes and skin.2. Hazards Identification
GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008Acute toxicity, Oral (Category 4), H302
Skin irritation (Category 2), H315
Eye irritation (Category 2), H319Labeling according GHS & Regulation (EC) No 1272/2008
GHS Label Elements
IrritantSignal Words: Warning
Hazard statements:
H302: Harmful if swallowed.
H315: Causes skin irritation.
H319: Causes serious eye irritation.Precautionary statements:
P264: Wash … thoroughly after handling.
P270: Do not eat, drink or smoke when using this product.
P280: Wear protective gloves/protective clothing/eye protection/face protection.
P330: Rinse mouth.
P362: Take off contaminated clothing and wash before reuse.
P301+312: IF SWALLOWED: Call a POISON CENTER or doctor/physician if you feel unwell.
P302+352: IF ON SKIN: Wash with soap and water.
P332+313: If skin irritation occurs: Get medical advice/attention.
P305+351+338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do – continue rinsing.
P337+313: If eye irritation persists get medical advice/attention.
P501: Dispose of contents/container to authorized agents only.Classification according to EU Directives 67/548/EEC or 1999/45/EC:
Xn Harmful
Xi Irritant
R22 Harmful if swallowed.
R36/38 Irritating to eyes and skin.3. Composition/Information on Ingredients
Ingredient: Potassium Iodide
CAS No.: 7681-11-0
EINECS EC Number: 231-659-4
Percent: 97 - 100%4. First Aid Measures
Always seek medical attention after first aid measures are provided.
Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Ingestion: Never give anything by mouth to an unconscious person. Get medical attention.
Skin Contact: Wipe off excess material from skin then immediately flush skin with plenty of water for at least 15 minutes. Remove contaminated clothing and shoes. Get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.
Eye Contact: Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Get medical attention immediately.5. Fire Fighting Measures
Flammability of the Product: Non-flammable.
Products of Combustion: Hydrogen Iodide, Iodine, Oxides of Potassium etc..
Fire: Potassium Iodide is not considered to be a fire hazard.
Fire Extinguishing Media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Use any means suitable for extinguishing surrounding fire.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures or when moistened under fire conditions, it may produce toxic or irritating fumes. On decomposition it may emit hydrogen iodide. Containers may explode on heating6. Accidental Release Measures
Small Spill: Avoid dust formation. Avoid breathing dust. Ensure adequate ventilation. Use appropriate tools to put the spilled solid in a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and dispose of according to local and regional authority requirements.
Large Spill: Avoid touching the spilled material. Do not let the product enter drains. Use a shovel to put the material into a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and allow to evacuate through the sanitary system.7. Handling and Storage
Do not breathe dust. Wear suitable protective clothing. In case of insufficient ventilation, wear suitable respiratory equipment.
Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Wash hands thoroughly after handling. Provide appropriate exhaust ventilation at places where dust is formed.
Keep in a tightly closed container, stored in a cool, dry, ventilated area. Protect against physical damage.8. Exposure Controls/Personal Protection
Airborne Exposure Limits: USA ACGIH, ACGIH TWA (ppm): 0.01 ppm Inhalable fraction
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice. Wash hands after handling.9. Physical and Chemical Properties
Appearance: Colorless white powder or crystals.
Odor: It is odorless.
Solubility: It is freely soluble in water. 76 parts in 100 parts water @ 25 deg. C
pH: 6-9.
Density: 3.13 g/mL at 20C (68F)
Molecular formula: KI
Molecular weight: 166
% Volatile by volume @ 21C (70F): -
Boiling Point: 1330C 2426F
Melting Point: 681C 1257F10. Stability and Reactivity
Stability: Potassium Iodide is stable under ordinary conditions of use and storage.
Hazardous Decomposition Products: It emits toxic iodide or hydrogen iodide fumes when heated to decomposition. It may form potassium oxide and hydrogen iodide and iodide.
Hazardous Polymerization: Will not occur.
Incompatibilities: Strong oxidizing agents, chlorinated compounds, metals & acids.
Conditions to Avoid: Incompatibles heat, light and moisture.11. Toxicological Information
Acute toxicity
Harmful if swallowed. Harmful if inhaled.
Toxicity data
LD50 Oral - mouse - 1000 mg/kg
LD50 Oral - Rat - 2799 mg/kg
Carcinogenic Effects: Not a reported carcinogen by IARC NTP ACGIH OSHA.
Mutagenic Effects: Mutagenic for mammalian somatic cells. Investigated as a mutagen, reproductive effector.
Teratogenic Effects: Iodine salts can cause deformity, illness, and death of a fetus..12. Ecological Information
Toxicity to fish: LC50 - Oncorhynchus mykiss (rainbow trout) - 2.190 mg/l - 96 h
Toxicity to daphnia and other aquatic invertebrates: EC50 - Daphnia - 2,7 mg/l - 24 h
Environmental Toxicity: This chemical is expected to cause little oxygen depletion in aquatic systems.
Toxicity of the Products of Biodegradation: The products of degradation and the product are not classed as toxic.13. Disposal Considerations
Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Processing, use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements.
14. Transport Information
US DOT, ADR/RID Classification: Not regulated.
Canada TDG Classification: Not regulated.
IATA: Not regulated.15. Regulatory Information
USA:
TSCA: Listed
SARA 302 Components: No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SARA 313 Components: No chemicals in this material are subject to the reporting requirements.
SARA 311/312 Hazards: Immediate (acute) health hazard Delayed (chronic) health hazard.
California Prop.65: Not Listed.
Health & Safety Reporting List: None of the chemicals are on the Health & Safety Reporting List.
Chemical Test Rules: None of the chemicals in this product are under a Chemical Test Rule.
Section 12b: None of the chemicals are listed under TSCA Section 12b.
TSCA Significant New Use Rule: None of the chemicals in this material have a SNUR under TSCA.
CERCLA Hazardous Substances and corresponding RQs: Not ListedCanada - WHMIS: CLASS D-2B:
Canada - DSL/NDSL: CAS# 7681-11-0 is listed on Canada's DSL List.
Canadian Ingredient Disclosure List: CAS# 7681-11-0 is not listed on the Canadian Ingredient Disclosure List.16. Other Information
Disclaimer:
***************************
Our company provides this Potassium Iodide SDS sheet in good faith but makes no representation as to its comprehensiveness or accuracy. This Potassium Iodide MSDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. The above information has been compiled from various sources and has the possibility of discrepancy and being out-dated information. Individuals receiving the information must exercise their independent judgment and do further search in determining its appropriateness for a particular purpose. In no case shall our company be liable to loss or damages by the product user.
***************************Potassium Iodide Manufacturers:
MUBY CHEMICALS GROUP
DONGRI-CHINCHBUNDER, MUMBAI 400009, INDIA
TEL: (OFFICE) 91-22-23770100, 91-22-23726950, 91-22-23774610, 23723564.e-mail: info@mubychem.com
Global or International Potassium Iodide Suppliers, Exporters, Importers, Manufacturers